686 research outputs found

    Performance Study of Acoustophoretic Microfluidic Silicon-Glass Devices by Characterization of Material- and Geometry-Dependent Frequency Spectra

    Get PDF
    The mechanical and electrical response of acoustophoretic microfluidic devices attached to an ac-voltage-driven piezoelectric transducer is studied by means of numerical simulations. The governing equations are formulated in a variational framework that, introducing Lagrangian and Hamiltonian densities, is used to derive the weak form for the finite element discretization of the equations and to characterize the device response in terms of frequency-dependent figures of merit or indicators. The effectiveness of the device in focusing microparticles is quantified by two mechanical indicators: the average direction of the pressure gradient and the amount of acoustic energy localized in the microchannel. Further, we derive the relations between the Lagrangian, the Hamiltonian and three electrical indicators: the resonance Q-value, the impedance and the electric power. The frequency response of the hard-to-measure mechanical indicators is correlated to that of the easy-to-measure electrical indicators, and by introducing optimality criteria, it is clarified to which extent the latter suffices to identify optimal driving frequencies as the geometric configuration and the material parameters vary.Comment: 15 pages, 10 figures, Supplementary Materia

    Diving with microparticles in acoustic fields

    Full text link
    Sound can move particles. A good example of this phenomenon is the Chladni plate, in which an acoustic wave is induced in a metallic plate and particles migrate to the nodes of the acoustic wave. For several years, acoustophoresis has been used to manipulate microparticles in microscopic scales. In this fluid dynamics video, submitted to the 30th Annual Gallery of Fluid Motion, we show the basic mechanism of the technique and a simple way of visualize it. Since acoustophoretic phenomena is essentially a three-dimensional effect, we employ a simple technique to visualize the particles in 3D. The technique is called Astigmatism Particle Tracking Velocimetry and it consists in the use of cylindrical lenses to induce a deformation in the particle shape, which will be then correlated with its distance from the observer. With this method we are able to dive with the particles and observe in detail particle motion that would otherwise be missed. The technique not only permits visualization but also precise quantitative measurements that can be compared with theory and simulations.Comment: Fluid dynamics video for the 30th Annual Gallery of Fluid Motion, Entry #84160 65th Annual Meeting of the American Physical Society, Division of Fluid Dynamics San Diego, CA, Nov 201

    Ultrasound-induced acoustophoretic motion of microparticles in three dimensions

    Get PDF
    We derive analytical expressions for the three-dimensional (3D) acoustophoretic motion of spherical microparticles in rectangular microchannels. The motion is generated by the acoustic radiation force and the acoustic streaming-induced drag force. In contrast to the classical theory of Rayleigh streaming in shallow, infinite, parallel-plate channels, our theory does include the effect of the microchannel side walls. The resulting predictions agree well with numerics and experimental measurements of the acoustophoretic motion of polystyrene spheres with nominal diameters of 0.537 um and 5.33 um. The 3D particle motion was recorded using astigmatism particle tracking velocimetry under controlled thermal and acoustic conditions in a long, straight, rectangular microchannel actuated in one of its transverse standing ultrasound-wave resonance modes with one or two half-wavelengths. The acoustic energy density is calibrated in situ based on measurements of the radiation dominated motion of large 5-um-diam particles, allowing for quantitative comparison between theoretical predictions and measurements of the streaming induced motion of small 0.5-um-diam particles.Comment: 13 pages, 8 figures, Revtex 4.

    Multiple-crystal X-ray topographic characterization of periodically domain-inverted KTiOPO4 crystal

    Get PDF
    A periodically domain-inverted KTiOPO4 crystal has been characterized for the first time by multiple-crystal multiple-reflection x-ray topography. The striation contrast within the domain- inverted regions has been revealed in high strain-sensitivity reflection topographs. The origin of formation of the striation contrast and the mechanism of domain inversion in KTiOPO4 are discussed in terms of the structural characteristics of KTiOPO4

    Moving towards high density clinical signature studies with a human proteome catalogue developing multiplexing mass spectrometry assay panels

    Get PDF
    A perspective overview is given describing the current development of multiplex mass spectrometry assay technology platforms utilized for high throughput clinical sample analysis. The development of targeted therapies with novel personalized medicine drugs will require new tools for monitoring efficacy and outcome that will rely on both the quantification of disease progression related biomarkers as well as the measurement of disease specific pathway/signaling proteins

    Surface behaviour of nco species on Rh(111) and polycrystalline Rh surfaces

    Get PDF
    Quasi-phase-matching (QPM) is a method to get tailored efficient second order nonlinear interactions [1]. Several techniques exist for fabrication of periodic domain structures in ferroelectric crystals for QPM frequency conversion. By far, electric field poling using lithographically patterned electrodes on the z-face of the crystal is the most common one [2]. High-quality periodically inverted ferroelectric domain structures in flux grown KTiOP 4 (KTP) crystals were fabricated already in the late 90's using this technique [3], and recently periodic domain sizes of few hundred nanometers were fabricated in 1 mm thick samples thanks to the quasi-one dimensional structure of KTP. It has recently also been shown that a slight Rb doping of the KTP crystal (RKTP) facilitates the periodic poling [4]. However, fabrication of two-dimensional (2D) domain structures in RKTP has not yet been investigated. A disadvantage with the lithographic patterning is that each sample needs to be patterned individually, which is tedious and time consuming. Moreover, when it comes to the small domain features, which are required by the next generation of nonlinear optical devices, a more versatile poling technique has to be developed due to the limitations of conventional photolithography. Structured silicon has been investigated as an alternative electrode for formation of 1D domains by contact poling in LiNb3 [5]. However, these electrodes were fabricated by wet etching and the sample thickness was limited to ∼200 μm.QC 20140619</p

    Acoustic radiation- and streaming-induced microparticle velocities determined by micro-PIV in an ultrasound symmetry plane

    Full text link
    We present micro-PIV measurements of suspended microparticles of diameters from 0.6 um to 10 um undergoing acoustophoresis in an ultrasound symmetry plane in a microchannel. The motion of the smallest particles are dominated by the Stokes drag from the induced acoustic streaming flow, while the motion of the largest particles are dominated by the acoustic radiation force. For all particle sizes we predict theoretically how much of the particle velocity is due to radiation and streaming, respectively. These predictions include corrections for particle-wall interactions and ultrasonic thermoviscous effects, and they match our measurements within the experimental uncertainty. Finally, we predict theoretically and confirm experimentally that the ratio between the acoustic radiation- and streaming-induced particle velocities is proportional to the square of the particle size, the actuation frequency and the acoustic contrast factor, while it is inversely proportional to the kinematic viscosity.Comment: 11 pages, 9 figures, RevTex 4-

    Label-free single-cell separation and imaging of cancer cells using an integrated microfluidic system

    Get PDF
    The incidence of cancer is increasing worldwide and metastatic disease, through the spread of circulating tumor cells (CTCs), is responsible for the majority of the cancer deaths. Accurate monitoring of CTC levels in blood provides clinical information supporting therapeutic decision making, and improved methods for CTC enumeration are asked for. Microfluidics has been extensively used for this purpose but most methods require several post-separation processing steps including concentration of the sample before analysis. This induces a high risk of sample loss of the collected rare cells. Here, an integrated system is presented that efficiently eliminates this risk by integrating label-free separation with single cell arraying of the target cell population, enabling direct on-chip tumor cell identification and enumeration. Prostate cancer cells (DU145) spiked into a sample with whole blood concentration of the peripheral blood mononuclear cell (PBMC) fraction were efficiently separated and trapped at a recovery of 76.2 ± 5.9% of the cancer cells and a minute contamination of 0.12 ± 0.04% PBMCs while simultaneously enabling a 20x volumetric concentration. This constitutes a first step towards a fully integrated system for rapid label-free separation and on-chip phenotypic characterization of circulating tumor cells from peripheral venous blood in clinical practice

    2DDB – a bioinformatics solution for analysis of quantitative proteomics data

    Get PDF
    BACKGROUND: We present 2DDB, a bioinformatics solution for storage, integration and analysis of quantitative proteomics data. As the data complexity and the rate with which it is produced increases in the proteomics field, the need for flexible analysis software increases. RESULTS: 2DDB is based on a core data model describing fundamentals such as experiment description and identified proteins. The extended data models are built on top of the core data model to capture more specific aspects of the data. A number of public databases and bioinformatical tools have been integrated giving the user access to large amounts of relevant data. A statistical and graphical package, R, is used for statistical and graphical analysis. The current implementation handles quantitative data from 2D gel electrophoresis and multidimensional liquid chromatography/mass spectrometry experiments. CONCLUSION: The software has successfully been employed in a number of projects ranging from quantitative liquid-chromatography-mass spectrometry based analysis of transforming growth factor-beta stimulated fi-broblasts to 2D gel electrophoresis/mass spectrometry analysis of biopsies from human cervix. The software is available for download at SourceForge

    Прилад для вимірювання розмірів деталей із низькомодульних матеріалів

    Get PDF
    Background: Enhanced secondary preventive follow-up after stroke or transient ischemic attack (TIA) is necessary for improved adherence to recommendations regarding blood pressure (BP) and low-density lipoprotein cholesterol (LDL-C) levels. We investigated whether nurse-led, telephone-based follow-up was more efficient than usual care at improving BP and LDL-C levels at 12 months after hospital discharge. Methods: We randomized 537 patients to either nurse-led, telephone-based follow-up (intervention) or usual care (control). BP and LDL-C measurements were performed at 1 month (baseline) and 12 months post-discharge. Intervention group patients who did not meet target values at baseline received additional follow-up, including titration of medication and lifestyle counselling, to reach treatment goals (BP &lt; 140/90 mmHg, LDL-C &lt; 2.5 mmol/L). Results: At 12 months, mean systolic BP, diastolic BP and LDL-C was 3.3 (95% CI 0.3 to 6.3) mmHg, 2.3 mmHg (95% CI 0.5 to 4.2) and 0.3 mmol/L (95% CI 0.1 to 0.4) lower in the intervention group compared to controls. Among participants with values above the treatment goal at baseline, the difference in systolic BP and LDL-C was more pronounced (8.0 mmHg, 95% CI 4.0 to 12.1, and 0.6 mmol/L, 95% CI 0.4 to 0.9). A larger proportion of the intervention group reached the treatment goal for systolic BP (68.5 vs. 56.8%, p = 0.008) and LDL-C (69.7% vs. 50.4%, p &lt; 0.001). Conclusions: Nurse-led, telephone-based secondary preventive follow-up, including medication adjustment, was significantly more efficient than usual care at improving BP and LDL-C levels by 12 months post-discharge
    corecore